GameSkillPro

Lesson Safety Overview · Job site, clothing, and height

Ladders and scaffolds

Elevated work uses scaffolds (usually safest platforms) or ladders. Place straight ladders at about 76° — base one-fourth of ladder length from the wall; extend 3 feet above the landing. Use fiberglass or wood for electrical work, not aluminum. Check load rating. On step ladders, do not stand on the top step.

1

Scaffolds: the safer elevated platform

When work is high or long-duration, scaffolds generally provide the safest working platforms. Job-site scaffold sections stack to height; adjustable feet level the base; X braces between end frames create a rigid platform.

Types you will see:

  • Fixed/stacked sections built from standard frames,
  • Rolling scaffolds with wheels (for level floors) — lock wheels after positioning,
  • Suspended/hanging scaffolds on cables for building exteriors, raised by crank or motor.

Use guardrails, deck planks, and tie-offs per manufacturer and OSHA when required.

2

Straight ladders: angle, extension, and feet

Straight ladders have rungs between two rails and safety feet to reduce slip. Before climbing, read the load capacity on the side label — common ratings include 200, 250, and 300 pounds. Include your weight, tools, and materials in that budget.

Set the ladder at about 76° to the structure. A practical rule: move the base away from the wall a distance equal to one-fourth the ladder length. A 20 ft ladder → base about 5 ft from the wall.

If the ladder provides access to a roof or platform, extend the top 3 feet above the landing so the climber can transition safely.

3

Electrical work: ladder material matters

Ladders for electrical work are usually wood or fiberglass. Aluminum ladders conduct electricity — avoid them for electrical tasks unless company policy explicitly allows specific conditions.

Wet or dirty fiberglass still demands care; treat any ladder near energized parts as part of the shock path planning you learned in current-effects lessons.

4

Step ladders: spreaders and top step

Step ladders are self-supporting with hinged front and back sections and a spreader locked open. Check load rating just like straight ladders.

Manufacturers warn: do not use the top step — balance becomes unsafe. Many people mistake the top step for the “top of the ladder”; the ladder top is the cap above the last usable step. Standing on the top step is a common fall cause.

5

Combining ladders, scaffolds, and PPE

Height work stacks hazards:

  • fall from ladder or scaffold,
  • contact with overhead conductors,
  • dropping tools on people below.

Use harness/lanyard when rules require, hard hat below overhead work, and barricades under scaffolds when objects could fall. Do not lean ladders on live buswork “just to reach” — plan access.

If wind, ice, or overload makes the platform feel wrong, it is wrong — stop and rebuild.

6

Field numbers to memorize

ItemRule of thumb
Straight ladder angle~76°
Base distance1/4 of ladder length
Extension above landing3 ft
Harness often requiredAbove 6 ft or per site rule
Electrical ladder materialFiberglass or wood, not aluminum
7

Rolling and suspended scaffolds — extra rules

On rolling scaffolds, lock all wheels before climbing. Never ride a rolling scaffold like a cart. Keep the floor level and clear of cords that could roll the base.

Suspended scaffolds depend on cable anchors and motors — inspect cables, counterweights, and brakes per the erector’s program. Electrical work from suspended platforms still requires clearance from overhead conductors; metal poles and ladders do not mix with bare lines.

8

Three-point contact and tool belts

When climbing any ladder, maintain three-point contact — two feet and one hand, or two hands and one foot. Carry tools on a belt or hoist line, not in your teeth or stacked in both hands.

Dropping a screwdriver from height injures people below and sends you reaching for balance. Plan material lifts before you climb.

9

Field case

Situation. A helper sets a 24 ft aluminum ladder against a service mast to reset a tripped overhead light, base almost against the wall for “stability,” top barely at the eave. The ladder slips; the helper grabs the mast.

How to think with this lesson.

  • Aluminum + electrical service = shock path risk.
  • Base too close → angle too steep → slip.
  • No 3 ft extension above landing made transition unsafe.

Learning conclusion: fiberglass/wood, 1/4 base distance, 76°, 3 ft extension, load rating — every time.

In the field

Symptom

Ladder slip, fall, or shock from ladder contact with energized parts

Where to look

Ladder material, angle, extension, feet, load label, overhead lines

Likely causes

  1. Aluminum near electricity
  2. wrong angle
  3. overloaded
  4. top step used on stepladder

What to measure

  1. Base distance = height/4
  2. extension ≥ 3 ft
  3. weight vs load rating

What not to do

  • Use aluminum for electrical work
  • climb unbraced scaffold
  • stand on top step

Checklist

  • I choose fiberglass or wood ladders for electrical work
  • I verify load capacity includes me, tools, and materials
  • I set straight ladders at ~76° (base 1/4 of length out)
  • I extend ladders 3 ft above landings used for access
  • I lock rolling scaffold wheels after moving
  • I do not use the top step of a step ladder

Common mistakes

Symptom Typical cause Action
Ladder slip at eave Base too close / wrong angle 1/4 length base distance; 76°
Shock from ladder Aluminum ladder near energized parts Fiberglass/wood; maintain clearance
Fall from stepladder Stood on top step Use last rated step only; use taller ladder
Scaffold tip Unlocked wheels or missing brace Lock wheels; install X braces per setup